Webpetsupply ATP3000/ATP3040 are low-noise, high-resolution fiber optic spectrometer. It employs 2048/4096 pixels CCD sensor spectral response covering UV to NIR wavelength. Readout speed reach up to 10MHz, low noise signal process circuit, and fast and accurate spectral data collection.
ATP3040 further improve SNR and dynamic range based on ATP3000, so measuring results have high stability and reliability, and they do not change with operating temperatures.
ATP3000/3040 supplies power directly via USB port, and outputs data via USB2.0/UART, and it's convenient to apply integration.
PN | CCD pixels | Cooling |
ATP3000 | 2048pixels | Uncooled CCD |
ATP3040 | 4096pixels | Uncooled CCD |
Detector | |
Conversion efficiency | 25uV/e- |
Detector type | Linear CCD sensor |
Effective pixels | ATP3000: 2048pixels ATP3040: 4096pixels |
Pixels dimension | ATP3000: 14μm×200μm ATP3040: 7μm×200μm |
Detector model | Hamamatsu S11639/ S13496 |
Sensitivity | 1300(V/lx.s) |
Dark noise | ATP3000: 8.3RMS@25℃ |
Optical parameter | |
Optical resolution | 0.01-1 nm(decide on slit and spectral range) |
Incident Interface | SMA905 connector or free space |
Dynamic range | ATP3000: 10000:1 |
confocal distance | 77.5 mm for incidence / 112 mm for output |
Working humidity | < 90%NC |
Wavelength range | 180-1100 nm(available in custom wavelength) |
SNR | ATP3000: >1000: 1 |
Physical parameters | |
Dimensions | 170×110×52 mm3 |
Weight | 0.8kg |
Sealing | Anti-sweat |
Optical configuration | |
Optical design | F/4 crossed C-T |
Incident slit | 5,10, 25, 50,100,150, 200 μm (optional, available in custom width) |
Electrical parameter | |
Power supply | DC 5V±10% |
Integration time | 1-65535 ms |
Operating current | <350 mA(uncooled), <3.0A(cooled) |
Storage temperature | -20°c to + 70 °c |
Operating temperature | -10°c to + 45°c |
- Resolution: 0.01-2 nm.
- Detector pixels:2048.
- High sensitivity:1300V(lx.s).
- Response range:from UV to NIR.
- Maximum readout speed:10MHz max.
- Optical path:crossed C-T.
- Integration time:1ms-65535ms.
- Power supply:USB port.
- Light input connector: SMA905 or free space.
- Data output connector:USB2.0 (High speed) or UART.
- Small volume, fast spectrophotometer
- Spectral analysis/Iradiance spectrophotometer analysis
- Transmission, absorbance measurement
- Reflectance detection
- Ellipsometer
- Laser wavelength measurement
- UV, VIS, and short wave NIR wavelength measurement
How to select High resolution & uncooled spectrometer from Webpetsupply?
Webpetsupply ATP3XXX series are high resolution and uncooled spectrometer.
ATP3000 (2048pixels) & ATP3040 (4096pixels) both uses crossed C-T, higher sensitivity, they are usually used to replace HR2000 and HR4000
ATP3030 (2048pixels) & ATP3034 (4096pixels) both uses M-shape C-T, higher resolution, low stray light, uv enhanced application is highly recommended.
ATP3330 (2048pixels) & ATP3334 (2048pixels) ) both uses M-shape C-T, higher resolution, low stray light, NIR range can also applicable to high resolution.
How many topology structure of optical path for a spectrometer?
There are commonly divided into 4 types of optical path, including crossed C-T, M-shape C-T, concave grating optical path, transmittance grating opitcal path.
Crossed C-T: ATP2000P,ATP2002, ATP2400, ATP1010, ATP5020P, ATP5040, ATP6500
M-shape C-T: ATP3030, ATP3034, ATP3330/4 ATP5030, ATP5034, ATP5330/4
Concave grating: ATP4230, ATP4020, ATP4050, ATP4070
let's see the M-shape optical path looks like a number "3", so our models uses the 3rd number "3" to indicate M-shape optical path models.
In generally, topology structure can decide resolution, sensitivity, stray light, and size of a spectrometer.
Crossed C-T topology structure employs better sensitivity and compact size.
M-shape C-T employs higher resolution and better stray light.
Concave grating optical path employs high stray light.
Which modular spectrometer can replace Ocean Insight FLAME-T-VIS-NIR-ES?
Webpetsupply ATP3040 Same performance as Ocean Insight FLAME-T-VIS-NIR-ES, with integration time 1ms-65s, 4096 pixels.