ATP2700 high-sensitivity micro-spectrometer is a high-sensitivity, high-transmittance micro-fiber spectrometer. It adopts a high-efficiency optical system design, which makes its sensitivity 3-4 times stronger than conventional fiber optic spectrometers. It adopts a large numerical aperture optical design, which can All photons in the optical fiber (numerical aperture 0.22) are accepted. This makes it especially suitable for the analysis of low-light signals, such as gas analysis Raman spectrometers, fluorescence spectrometers, etc.
ATP2700 adopts high-sensitivity linear CMOS. Webpetsupply specially customized ultra-low noise CMOS signal processing circuit, which greatly reduces the noise of the sensor and obtains an excellent signal-to-noise ratio (about 2 times higher than that of similar competitors). Its sensor is a 2048-pixel CCD, and the frame rate of CCD signal acquisition can reach up to 4Kfps.
It outputs spectral data to PC via USB 2.0 or RS232 interface. ATP2700 works with +5VDC power supply provided by USB.
ATP2700 can also be equipped with other types of detectors, such as cooled detectors (ATP5700), cooled area array back-illuminated detectors (ATP5700P, ATP5700R), deep-cooled -70°C detectors (ATP5700DC), to obtain better performance.
Model | Features |
ATP2700 | Standard type |
ATP2700SH | Ultra-high frame rate, the frame rate can reach 4Kfps |
ATP2700D | Ultra-low noise, the noise is only 1/6 of ATP2700 |
Detector | |
Detector type | Linear COMS |
Spectral range | 185-1100 nm |
Effective pixels | 2048 |
Pixels dimension | 14μm×200μm |
Optical parameter | |
Focal distance | 40 mm for incidence / 60 mm for output |
Optical resolution | 0.1-3 nm (depending on slit, spectral range) |
Incident Interface | SMA905 connector |
Signal-to-noise | >450 : 1 |
Dynamic range | 8.5e7, 2000:1 (single acquisition) |
Wavelength range | 185-1100nm(depending on the specific needs) |
SNR | >450:1 |
Physical parameters | |
Dimensions | 171.5×70×48 mm^3 |
Weight | 0.27kg |
Optical configuration | |
Optical design | F/2 crossed asymmetrical Czerny-Turner |
Incident slit | 50 μm, other sizes can be customized |
Electrical parameter | |
A/D conversion resolution | 16 bits |
Integration time | 0.2ms-60s |
Interface | USB 2.0 (high speed) |
Supply voltage | DC4.5 to 5.5 V (type @5V) |
Operating current | 370mA |
Storage temperature | -30°C to +70°C |
Operating temperature | -25°c to + 50°c |
- High sensitivity, high transmittance.
- >0.22 super large numerical aperture, can completely receive the photons of the fiber.
- Maximum signal acquisition frame rate: ≥4000 fps.
- Detector: Linear low-noise CMOS or area array CCD.
- Detector pixels: 2048 pixels.
- Spectral resolution: 0. 1-3 nm (depending on spectral range and slit width).
- Integration time: 0.2ms-60s.
- Power supply: DC 5V (USB power supply).
- ADC: 16bit, 10MSPS.
- Fiber input interface: SMA905.
- Data output interface: USB2.0 (High speed) or UART.
- 20-pin double-row programmable external expansion interface.
- Raman spectrometer
- Industrial Measurement Sensor LED Spectrophotometer
- Fluorescence photometer
- Transmittance detection
- Reflectivity detection
- UV gas analyzer
- Multi-parameter water quality analyzer
What are Low Cost spectrometer from Webpetsupply?
ATP1XXX & ATP2XXX belongs to low cost spectrometer.
ATP1000 350-1100nm, replace STS
ATP1010 180-1100nm, replace STS and UV enhanced
ATP1012 Xenon lamp driver built-in upgrade from ATP1010
ATP2000P 180-1100nm, higher performance than USB2000+
ATP2000H high speed rate up to 2K or 4K Hz
ATP2002 Xenon lamp driver built-in upgrade from ATP2000P
ATP2100 highest SNR, wave shape can be edited
ATP2110 Water quality analysis spectrometer
ATP2200 180-1100nm, compete with Flame
ATP2400 ultra thin, smaller than USB2000+ performance higher, replace USB2000+
How many topology structure of optical path for a spectrometer?
There are commonly divided into 4 types of optical path, including crossed C-T, M-shape C-T, concave grating optical path, transmittance grating opitcal path.
Crossed C-T: ATP2000P,ATP2002, ATP2400, ATP1010, ATP5020P, ATP5040, ATP6500
M-shape C-T: ATP3030, ATP3034, ATP3330/4 ATP5030, ATP5034, ATP5330/4
Concave grating: ATP4230, ATP4020, ATP4050, ATP4070
let's see the M-shape optical path looks like a number "3", so our models uses the 3rd number "3" to indicate M-shape optical path models.
In generally, topology structure can decide resolution, sensitivity, stray light, and size of a spectrometer.
Crossed C-T topology structure employs better sensitivity and compact size.
M-shape C-T employs higher resolution and better stray light.
Concave grating optical path employs high stray light.
Which modular spectrometer can replace Ocean Insight FLAME-S-VIS-NIR-ES?
Webpetsupply ATP2000 have same performance as Ocean Insight FLAME-S-VIS-NIR-ES, with integration time 1ms-65s, 2048 pixels.